1) 5'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
2) Fanless design, quiet, energy-saving, and clean, which reduces the possibility of cross-infection.
3) All-round monitoring for adults, pediatrics, and neonates.
4) With the standard interface, oxygen graph, trend graph, big character interface, and view bed, convenient to observe.
5)Finish all operations with keys and knobs.
6) Maximum 8-channel waveform synchronous display.
7) Display 7-lead ECG waveform on one screen, cascade ECG waveform display
8) Adopt digital SpO2 technology, anti-motion, and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
9) Heart rate variability (HRV) analysis function
10) NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
11) Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
12) Drug concentration calculation and titration table functions.
13) One-touch printing of trend graph
14) Connect to the Central Monitoring System by 3G, Wi-Fi, or wired mode.
15) AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
16) Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary). Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1) ECG Heart rate(HR)
ECG waveform
Arrhythmia and ST-segment analysis
2) RESP Respiration rate(RR)
Respiration waveform
3) SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4) NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5) TEMP T1, T2, TD
6) IBP(optional) CH1:SYS, DIA,MAP
CH2:SYS, DIA, MAP
IBP waveform
7) CO2(optional) EtCO2
InsCO2:Inspired Minimum CO2
AwRR: Air Way Respiration
It has abundant functions, such as audible and visual alarms, trend data storage and output, NIBP measurement, alarm event marking, drug concentration calculation, etc.
Performance ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR: Measurement and alarm range: 15~350 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0 mV ~ +2.0 mV
Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
Accessories
1) Adult fingertip SpO2 probe (5-pin)
2) Adult NIBP cuff
3) NIBP extension tube
4) ECG lead cable
5) ECG electrode
6) Temperature probe
7) Power cord
8) User Manual
RESP Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0~150 rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP Method: Oscillometry
Mode: Manual/AUTO/STAT
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Max mean deviation: ±5 mmHg
Max standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
SpO2 Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP
Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC Accuracy: ±0.1 ºC
EtCO2 Method: Sidestream or Mainstream
Measuring Range: 0~150mmHg
Resolution: 0~69 mmHg, 0.1 mmHg 70~150 mmHg, 0.25 mmHg
Accuracy: 0~40 mm Hg ±2 mm Hg 41~70 mm Hg ±5% 71~100 mm Hg ±8% 101~150 mm Hg ±10% AwRR
Range: 2~150 rpm AwRR Accuracy: ±1BPM Apnea Alarm: Yes
IBP Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range: -10~300 mmHg Resolution 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater
Power supply: 100-240V~, 50/60Hz Safety classification: Class I, type CF defibrillation-proof applied part